Skip to content
IgshpaIgshpa
  • Home
  • Pages
    • About IGSHPA
  • Courses
    • Geothermal Energy and Ground Source Heat Pumps – An Overview
    • GSHP Residential Service Technician Online Training Course – $400 Member Price*
    • GHSP Residential Installer Online Training Course – $400 Member Price*
    • Prerequisite Modules – Residential/Light Commercial GHXI (Ground Heat Exchanger Installer) – $345 Member Price*
    • Full Course – Residential/Light Commercial GHXI (Ground Heat Exchanger Installer) Course – $895 Member Price*
    • DOE Energy Skilled Recognition Courses – Member Price
    • DOE Energy Skilled Recognition Courses – Non-Member Price
    • Selecting a Ground Source Heat Pump Team
  • Contact
    • Contact Us
  • Shop
  • My Account
IgshpaIgshpa
  • Home
  • Pages
    • About IGSHPA
  • Courses
    • Geothermal Energy and Ground Source Heat Pumps – An Overview
    • GSHP Residential Service Technician Online Training Course – $400 Member Price*
    • GHSP Residential Installer Online Training Course – $400 Member Price*
    • Prerequisite Modules – Residential/Light Commercial GHXI (Ground Heat Exchanger Installer) – $345 Member Price*
    • Full Course – Residential/Light Commercial GHXI (Ground Heat Exchanger Installer) Course – $895 Member Price*
    • DOE Energy Skilled Recognition Courses – Member Price
    • DOE Energy Skilled Recognition Courses – Non-Member Price
    • Selecting a Ground Source Heat Pump Team
  • Contact
    • Contact Us
  • Shop
  • My Account

A Model of Personality

  • Home
  • Quiz
  • A Model of Personality
Breadcrumb Abstract Shape
Breadcrumb Abstract Shape
Breadcrumb Abstract Shape

A Model of Personality

  • 17 Jan, 2024
  • Com 0

Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat.

Time limit: 0

Quiz Summary

0 of 96 Questions completed

Questions:

Information

You have already completed the quiz before. Hence you can not start it again.

Quiz is loading…

You must sign in or sign up to start the quiz.

You must first complete the following:

Results

Quiz complete. Results are being recorded.

Results

0 of 96 Questions answered correctly

Your time:

Time has elapsed

You have reached 0 of 0 point(s), (0)

Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)

Categories

  1. Not categorized 0%
  1. Review
  2. Answered
  3. Correct
  4. Incorrect
  1. Question 1 of 96
    1. Question

    A ground heat exchanger piping configuration that is designed to allow the circulating fluid to travel in a single flow path is defined as which type of system?

    Correct
    Incorrect
  2. Question 2 of 96
    2. Question

    A Ground Source Heat Pump System (GSHP) that is designed in such a manner to extract more energy from the earth during the heating mode than it will reject to the earth in the cooling mode or to reject more energy to the earth in the cooling mode than it will extract in the heating mode is the definition of which type of load?

    Correct
    Incorrect
  3. Question 3 of 96
    3. Question

    A pipe that has been inserted to the bottom of a vertical borehole to allow for the introduction of a grouting material into the borehole is defined by which term?

    Correct
    Incorrect
  4. Question 4 of 96
    4. Question

    A procedure consisting of the construction of a vertical borehole; satisfactory installation of a u-bend loop and grout material; connection of the loop, after a sufficient waiting period, to equipment designed to heat and circulate water through the loop; and documentation of the water temperatures that return from the attached vertical piping to be analyzed at a later time is defined by which term?

    Correct
    Incorrect
  5. Question 5 of 96
    5. Question

    A straight, stiff and weighted material should be added to the bottom of the u-bend assembly prior to manual insertion into a fluid-filled vertical borehole to overcome and offset buoyancy forces of the drilling fluid and which other variable?

    Correct
    Incorrect
  6. Question 6 of 96
    6. Question

    An increase in which variable for a horizontally trenched ground heat exchanger would allow for less feet of trench (shorter trench lengths)?

    Correct
    Incorrect
  7. Question 7 of 96
    7. Question

    An interior piping system serving multiple ground source heat pumps that utilizes a single pumping station to provide flow to all heat pumps within the system is defined as which type of pumping system?

    Correct
    Incorrect
  8. Question 8 of 96
    8. Question

    Antifreeze is required for all geothermal heat pump applications

    Correct
    Incorrect
  9. Question 9 of 96
    9. Question

    As a general rule, the exterior portion of the ground loop piping should remain buried at which depth range?

    Correct
    Incorrect
  10. Question 10 of 96
    10. Question

    At which point should the discharge end of a tremie pipe remain throughout the entire grouting process?

    Correct
    Incorrect
  11. Question 11 of 96
    11. Question

    Bentonite grouting material will be affected in which way when mixed with high temperature water?

    Correct
    Incorrect
  12. Question 12 of 96
    12. Question

    Cooling Rate divided by Energy Consumption Rate is the definition of:

    Correct
    Incorrect
  13. Question 13 of 96
    13. Question

    Crystalline, Granular, Microscopic and Glassy are terms used to refer to which physical property of rock?

    Correct
    Incorrect
  14. Question 14 of 96
    14. Question

    During ground heat exchanger installation, what procedure should be performed to prevent any foreign materials from entering the unconnected (un-headered) piping of the ground heat exchanger?

    Correct
    Incorrect
  15. Question 15 of 96
    15. Question

    Eliminating the possibility of the ground heat exchanger circulating fluid being exposed to contaminants during heat pump system operation is an advantage of using which type of flow center (flow module or pump module)?

    Correct
    Incorrect
  16. Question 16 of 96
    16. Question

    Fine grained soils are defined as soils consisting of particles that are small enough to pass through which size of sieve during a sieve analysis?

    Correct
    Incorrect
  17. Question 17 of 96
    17. Question

    For maximum ground heat exchanger performance, the grout material utilized should have a thermal conductivity in what relation to the thermal conductivity of the geological formation?

    Correct
    Incorrect
  18. Question 18 of 96
    18. Question

    For single-capacity heat pumps installed in heating dominant climates, the heat pump unit should not be over sized more than how much of the peak block sensible cooling load?

    Correct
    Incorrect
  19. Question 19 of 96
    19. Question

    Fragmented particles or grains that have been cemented (formed) together to form a single, solid rock mass is defined as which characteristic of rock texture?

    Correct
    Incorrect
  20. Question 20 of 96
    20. Question

    Grout volume for a particular borehole is calculated based on the size of the u-bend pipes to be placed in the borehole and which other variable?

    Correct
    Incorrect
  21. Question 21 of 96
    21. Question

    Grouting of a vertical ground heat exchanger is important for environmental and which other reason?

    Correct
    Incorrect
  22. Question 22 of 96
    22. Question

    If a distributed pumping system is used on the interior piping portion of a pressurized heat pump system, which component should be installed to prevent backflow of circulating fluid through a heat pump not in operation?

    Correct
    Incorrect
  23. Question 23 of 96
    23. Question

    If a rock of unknown properties appears to be granular and harder than a steel knife blade, which petrologic group would the rock be assigned to?

    Correct
    Incorrect
  24. Question 24 of 96
    24. Question

    If each individual ground loop of the ground heat exchanger can be brought back to a central point without excessive run distances for one or more loops, which header system is used?

    Correct
    Incorrect
  25. Question 25 of 96
    25. Question

    In horizontal ground heat exchanger applications, which of the following actions would be taken to account for the shrinking of a heavy-clay soil away from the heat exchanger piping?

    Correct
    Incorrect
  26. Question 26 of 96
    26. Question

    In terms of designing an HVAC system, which load refers to the amount of moisture in the air of a conditioned space?

    Correct
    Incorrect
  27. Question 27 of 96
    27. Question

    In the cooling mode of a water-to-air Ground Source Heat Pump (GSHP), the water-to-refrigerant heat exchanger serves as which component of the refrigerant cycle.

    Correct
    Incorrect
  28. Question 28 of 96
    28. Question

    In which state of soil consistency can the soil be rapidly deformed or molded without rebounding elastically, changing volume, cracking or crumbling?

    Correct
    Incorrect
  29. Question 29 of 96
    29. Question

    Is it correct to assume that 500 sq.ft. per ton is always a good sizing rule

    Correct
    Incorrect
  30. Question 30 of 96
    30. Question

    It is ok to add water to thin out grout if having trouble with pumping.

    Correct
    Incorrect
  31. Question 31 of 96
    31. Question

    Large amounts of expansion and contraction with changes in water content are characteristics of which type of soil?

    Correct
    Incorrect
  32. Question 32 of 96
    32. Question

    Mixing of high-solids bentonite grout should be done with which type of mixer?

    Correct
    Incorrect
  33. Question 33 of 96
    33. Question

    Moisture content increases ground thermal conductivity.

    Correct
    Incorrect
  34. Question 34 of 96
    34. Question

    Over sizing of the heat pump, equipment can cause which of the following issues during off-peak operation?

    Correct
    Incorrect
  35. Question 35 of 96
    35. Question

    Pressure drop (feet of head per 100 feet of pipe for a given fluid type / temperature / flow rate) multiplied by the total equivalent length of each type and size of pipe in the heat pump system flow path is defined by which term?

    Correct
    Incorrect
  36. Question 36 of 96
    36. Question

    The average temperature of the soil and/or rock into which a vertical ground heat exchanger will be installed is defined by which term?

    Correct
    Incorrect
  37. Question 37 of 96
    37. Question

    The Bin Method of energy load analysis is best suited for which type of building?

    Correct
    Incorrect
  38. Question 38 of 96
    38. Question

    The design of a closed-loop ground heat exchanger consists of selecting a ground heat exchanger configuration that will provide the required ground load demand of the heat pump and which other variable?

    Correct
    Incorrect
  39. Question 39 of 96
    39. Question

    The desuperheater heat exchanger is sized to limit its heat exchange capacity to which typical range of the heat pump system’s capacity?

    Correct
    Incorrect
  40. Question 40 of 96
    40. Question

    The measure of the resistance to heat transfer between the circulating fluid inside the pipe of a vertical ground heat exchanger and the borehole wall is defined by which term?

    Correct
    Incorrect
  41. Question 41 of 96
    41. Question

    The placement of a low permeability material into the annular space between a borehole wall and the pipes (ground heat exchanger) suspended in the borehole is defined by which term?

    Correct
    Incorrect
  42. Question 42 of 96
    42. Question

    The point at which a flowing fluid transitions from laminar to turbulent flow is defined by which term?

    Correct
    Incorrect
  43. Question 43 of 96
    43. Question

    The portion of the ground heat exchanger where the smaller diameter ground loops are connected to the larger diameter supply and return piping is defined by which term?

    Correct
    Incorrect
  44. Question 44 of 96
    44. Question

    The rate at which heat energy is transported through a material due to a temperature difference across the material is defined by which term?

    Correct
    Incorrect
  45. Question 45 of 96
    45. Question

    The state in which a soil is either in suspension or behaves like a viscous fluid is which state of soil consistency?

    Correct
    Incorrect
  46. Question 46 of 96
    46. Question

    The temperature of the soil in the top 20 feet of the earth’s surface varies with location, depth and which other variable?

    Correct
    Incorrect
  47. Question 47 of 96
    47. Question

    The texture and fabric characteristics of rocks are best observed by examining which form of rock specimen?

    Correct
    Incorrect
  48. Question 48 of 96
    48. Question

    The volume of grouting material required for a particular job depends on the annular volume between the ground heat exchanger and which other variable?

    Correct
    Incorrect
  49. Question 49 of 96
    49. Question

    To avoid bridging and dilution of grout materials; grout should be placed into a vertical borehole by which method?

    Correct
    Incorrect
  50. Question 50 of 96
    50. Question

    What fluid is required to fill and flush/purge the piping of a ground source heat pump system?

    Correct
    Incorrect
  51. Question 51 of 96
    51. Question

    What is the minimum bend radius for HDPE pipe?

    Correct
    Incorrect
  52. Question 52 of 96
    52. Question

    What is the minimum flow rate required to completely remove air from a piping system?

    Correct
    Incorrect
  53. Question 53 of 96
    53. Question

    What is the minimum recommended distance to locate ground heat exchanger piping (excluding supply and return piping) from the footing or foundation of a building?

    Correct
    Incorrect
  54. Question 54 of 96
    54. Question

    What is the recommended location to install pressure/temperature (P/T) measurement ports on interior heat pump system piping?

    Correct
    Incorrect
  55. Question 55 of 96
    55. Question

    What loads are used to size and select the equipment for a system and design the air distribution system?

    Correct
    Incorrect
  56. Question 56 of 96
    56. Question

    When compared to each other, which of the following soils or soil compositions will result in a higher value of thermal conductivity?

    Correct
    Incorrect
  57. Question 57 of 96
    57. Question

    When flushing and purging the interior piping of a multiple heat pump system, the flow path to which heat pump should be flushed and purged first?

    Correct
    Incorrect
  58. Question 58 of 96
    58. Question

    When in the design process of design and layout of a ground heat exchanger should the designer conduct a site visit to evaluate the suitability for ground heat exchanger application?

    Correct
    Incorrect
  59. Question 59 of 96
    59. Question

    When performance testing a ground source heat pump system, which of the following procedures will be used to estimate the water flow rate through the heat pump?

    Correct
    Incorrect
  60. Question 60 of 96
    60. Question

    When performing head loss (pressure drop) calculations for flushing and purging pump sizing, how many flow paths (loops) of a parallel ground heat exchanger should be selected for the calculations?

    Correct
    Incorrect
  61. Question 61 of 96
    61. Question

    When performing proper flow test procedures through a ground heat exchanger, a significant increase from the calculated expected pressure drop through a supply and return circuit would indicate which occurrence?

    Correct
    Incorrect
  62. Question 62 of 96
    62. Question

    When using wet/mud rotary drilling techniques for vertical borehole construction, what material carries the drill cuttings from the bottom of the borehole to the surface?

    Correct
    Incorrect
  63. Question 63 of 96
    63. Question

    Which classification of soil can be pulverized easily under finger pressure (slight pressure) to a smooth powdery consistency when it is dry?

    Correct
    Incorrect
  64. Question 64 of 96
    64. Question

    Which component of supplemental domestic how water generation operates as an override on/off switch to stop water heating when the water reaches a preset high-temperature limit?

    Correct
    Incorrect
  65. Question 65 of 96
    65. Question

    Which component of the ground heat exchanger piping connects the active legs (loops) of the heat exchanger to the interior piping system?

    Correct
    Incorrect
  66. Question 66 of 96
    66. Question

    Which component of vertical borehole construction may be necessary during the drilling process but should be removed from the completed borehole if possible?

    Correct
    Incorrect
  67. Question 67 of 96
    67. Question

    Which component should be installed to facilitate ground heat exchange piping location in the event that service is necessary?

    Correct
    Incorrect
  68. Question 68 of 96
    68. Question

    Which configuration will require the least amount of surface area for a buried ground heat exchanger?

    Correct
    Incorrect
  69. Question 69 of 96
    69. Question

    Which device that will prevent over sizing the heat pump in cooling capacity should be included in the design of a ground source heat pump system in a heating dominant climate where the ground source heat pump is not designed to deliver 100% of the heating capacity?

    Correct
    Incorrect
  70. Question 70 of 96
    70. Question

    Which document is developed by the ground heat exchanger designer to serve as documented location of the ground heat exchanger as well as various utility installations and permanent structures or boundaries?

    Correct
    Incorrect
  71. Question 71 of 96
    71. Question

    Which DR pipe will have the thickest wall

    Correct
    Incorrect
  72. Question 72 of 96
    72. Question

    Which energy analysis method is the simplest, but least reliable, method to determine the amount of energy a building’s heating/cooling system will use in a given year?

    Correct
    Incorrect
  73. Question 73 of 96
    73. Question

    Which fine grained soil classification test consists of shaking a moist soil sample in order to observe the appearance (or lack thereof) of water on the surface of the sample?

    Correct
    Incorrect
  74. Question 74 of 96
    74. Question

    Which ground heat exchanger piping configuration allows for fluid flow through two or more possible flow paths in the closed loop circuit?

    Correct
    Incorrect
  75. Question 75 of 96
    75. Question

    Which material is used as an additive to bentonite based grouts to increase …

    Correct
    Incorrect
  76. Question 76 of 96
    76. Question

    Which material will prevent leakage of surface or near surface contaminants downward along a vertical ground heat exchanger?

    Correct
    Incorrect
  77. Question 77 of 96
    77. Question

    Which number represents the minimum Reynolds Number required to achieve turbulent flow through a circular pipe within the Ground Source Heat Pump Industry?

    Correct
    Incorrect
  78. Question 78 of 96
    78. Question

    Which of the eight petrologic groups of rock classification contain rocks with the highest range of thermal conductivity values?

    Correct
    Incorrect
  79. Question 79 of 96
    79. Question

    Which of the following is an optional loop for a complete closed-loop Ground Source Heat Pump (GSHP) system?

    Correct
    Incorrect
  80. Question 80 of 96
    80. Question

    Which of the following issues could be caused by an undersized ground heat exchanger?

    Correct
    Incorrect
  81. Question 81 of 96
    81. Question

    Which of the following issues could cause water to leak from the heat pump unit with no presence of leaks in the circulating fluid piping?

    Correct
    Incorrect
  82. Question 82 of 96
    82. Question

    Which of the following scenarios would cause the amount of grout material being used to completely grout a vertical borehole to be considerably higher than the amount calculated?

    Correct
    Incorrect
  83. Question 83 of 96
    83. Question

    Which of the following term expresses the efficiency of heat pump systems (air source or water source) in the heating mode?

    Correct
    Incorrect
  84. Question 84 of 96
    84. Question

    Which of the following term is defined by the ratio of a building’s sensible cooling load to its total cooling load?

    Correct
    Incorrect
  85. Question 85 of 96
    85. Question

    Which optional component can be installed inside the heat pump equipment to provide supplemental domestic hot water generation?

    Correct
    Incorrect
  86. Question 86 of 96
    86. Question

    Which point in the installation process of a ground source heat pump system should an antifreeze agent be added to the circulating fluid (if used)?

    Correct
    Incorrect
  87. Question 87 of 96
    87. Question

    Which portion of a ground source heat pump system should be flushed and purged of air and debris first?

    Correct
    Incorrect
  88. Question 88 of 96
    88. Question

    Which practice would increase the likelihood of detecting a flow restriction in the ground heat exchanger during a proper flow test?

    Correct
    Incorrect
  89. Question 89 of 96
    89. Question

    Which procedure is performed to remove all air and debris from within the ground source heat pump piping system?

    Correct
    Incorrect
  90. Question 90 of 96
    90. Question

    Which product is added to water to reduce the freezing point of the fluid confined in a ground heat exchanger?

    Correct
    Incorrect
  91. Question 91 of 96
    91. Question

    Which property is the least reliable criteria for the identification of rocks?

    Correct
    Incorrect
  92. Question 92 of 96
    92. Question

    Which scenario would represent that a borehole has been completely and properly grouted?

    Correct
    Incorrect
  93. Question 93 of 96
    93. Question

    Which two (2) piping materials are suitable for use in ground heat exchanger applications?

    Correct
    Incorrect
  94. Question 94 of 96
    94. Question

    Which type of flow center (flow module or pump module) maintains positive suction pressure on the pump(s) via a tank or column of fluid?

    Correct
    Incorrect
  95. Question 95 of 96
    95. Question

    Which type of pump is defined as moving a confined volume of fluid through the pump by some combination of moving parts, and is ideal for the pumping of grout material?

    Correct
    Incorrect
  96. Question 96 of 96
    96. Question

    Which type of water is mandatory for proper mixing and hydration of bentonite grouting material?

    Correct
    Incorrect

Search

Categories

  • Blogs
  • Directory
  • Job Board
  • News

Categories

  • Blogs (8)
  • Directory (144)
  • Job Board (6)
  • News (14)

Tags

$10M Available 2025 conference annual conference C448 co-op training Connecticut CSA Design and Installation Standard District of Columbia electric co-op Engineer gaoi GAOI 2025 Georgia Geothermal Heat Pump geothermal technology Ground Source Heat Pump GSHP GSHP Standard IGSHPA IGSHPA/GAOI IGSHPA 2025 IGSHPA conference Illinois Indiana Large Scale Thermal Projects Maine Massachusetts Michigan New Hampshire New York North Carolina Ohio Pennsylvania Practice Leader Public Review Rhode Island Senior Mechanical Engineer Service Technician South Carolina Tennessee train-the-trainer Vermont Virginia West Virginia

Archives

  • September 2024
  • August 2024
  • July 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • February 2024
  • January 2024
  • December 2023
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • July 2023
  • May 2023
Copyright International Ground Source Heat Pump Association. All Rights Reserved.
IgshpaIgshpa

Confirmation

You are leaving the Exam. Do you want to continue to exit?